Page 95
Communication: Monitoring Station
Parameter
Default
Range
Controls
Allows to program control related to operation with the monitoring station.
Handshake
NO
YES: All LEDs on the WiComm Pro main panel light for one second when the
handshake signal is received from the Monitoring Station's receiver.
NO: No indication for establishing communication with the Monitoring Station's
receiver.
Kiss-Off Y/N
NO
YES: All LEDs on the WiComm Pro main panel light for one second and an
audible sound is emitted when the kissoff signal is received from the Monitoring
Station's receiver.
NO: No indication for establishing communication with the Monitoring Station's
receiver.
SIA Text
Not Applicable
Random MS Test
YES: At First power up the system will set a random hour which then becomes
the fixed hour for the panel to report periodic testing to the monitoring station.
This time can be viewed under the Periodic test timer fields.
NO: The periodic test will be according to the time defined by the installer
defined under the MS periodic timer
Parameters
Allows to program parameters related to operation with the Monitoring Station.
MS Retries
08
01-15
The number of times the system redials the Monitoring Station after failing to
establish communication.