Page 97
Communication: Monitoring Station
Parameter
Default
Range
Cancel Delay
5 min
0-255 min
If an alarm is sent in error, it is possible for the Monitoring Station to receive a
Cancel Alarm Code, sent subsequently to the initial Alarm Code. This happens if
a valid User Code is entered to reset the alarm in the Cancel Delay time window
that starts after the defined Abort Alarm time is over.
Note: Cancel Alarm report code should be defined.
Listen In
N/A
Not Applicable
Confirmation
The confirmation times relate to the Zone Sequential Confirmation.
Confirm Start (Confirm delay time)
0
0-120 min
Specifies that the system cannot start a sequential confirmation process
until the timer has expired. This time starts when the system has set and
will prevent confirmed alarms being generated in situations when a
person has been accidentally locked in the building.
Confirm Time Window
030
30-60 min
Specifies a time period that starts when an alarm is triggered for the
first time. If a second alarm is triggered before the end of the
confirmation time window, the system will send a confirmed alarm to
the monitoring station.
No Arm
0
0-12 weeks
A No Arm code will be sent to the Monitoring Station if no arming or disarming
has been established during the time defined (1-12 weeks).
(0=not activated)