EasyManua.ls Logo

Risco RW332M - Page 64

Risco RW332M
157 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 58
Zones: Parameters
Parameter
Default
Range
LED Enable Y/N (Only for 2 Way PIR and 2 Way
WatchOUT)
Y/N
Defines the LED operation mode.
YES: Detector's LED activated
NO: Detector's LED deactivated
Abort Alarm Y/N
This parameter defines whether a zone alarm report to the monitoring
station will be immediate or delayed:
YES: A report to the MS will be delayed according to the Abort Time Delay
parameter (Communication > MS > MS Times > Abort Alarm).
Note: If a valid user code is entered to reset the alarm within the cancel delay time
(Communication > MS > MS Times > Cancel Report), a cancel report
alarm code will be sent to the monitoring station.
NO: A report to the MS will be sent immediately.
Detection Mode (Only for 2 Way Detectors)
Normal
Fast (Walk Test): When the detector is in disarm it will transmit after each detection
Normal (Default): When the detector is in disarm, there will be 2.5 minutes of
“dead time” between detection transmissions.
Note: For both options, when the detector is armed it will transmit after each detection.
Presence
Enable/Disable
A zone that is set as Presence will send a push notification to the end-user when
triggered during disarm state:
1) Enable or 2) Disable sending a push notification to the end-user.
Note: The Presence push notifications option must also be selected in the RISCO Cloud for the
notifications to be sent to the end-user’s smartphone. he Presence zone can also be muted
via the RISCO Cloud.
Sensitivity (Only for 2 Way PIR and 2 Way WatchOUT)
Defines the PIR sensitivity of the detector.
Low
Medium (2 Way WatchOUT)
High
Maximum (2 Way WatchOUT)
Camera Parameters (Only for 2 Way eyeWAVE PIR Cameras)
Images at Alarm
3