LED Enable Y/N (Only for 2 Way PIR and 2 Way
WatchOUT)
Defines the LED operation mode.
YES: Detector's LED activated
NO: Detector's LED deactivated
This parameter defines whether a zone alarm report to the monitoring
station will be immediate or delayed:
YES: A report to the MS will be delayed according to the Abort Time Delay
parameter (Communication > MS > MS Times > Abort Alarm).
Note: If a valid user code is entered to reset the alarm within the cancel delay time
(Communication > MS > MS Times > Cancel Report), a cancel report
alarm code will be sent to the monitoring station.
NO: A report to the MS will be sent immediately.
Detection Mode (Only for 2 Way Detectors)
• Fast (Walk Test): When the detector is in disarm it will transmit after each detection
• Normal (Default): When the detector is in disarm, there will be 2.5 minutes of
“dead time” between detection transmissions.
Note: For both options, when the detector is armed it will transmit after each detection.
A zone that is set as Presence will send a push notification to the end-user when
triggered during disarm state:
1) Enable or 2) Disable sending a push notification to the end-user.
Note: The Presence push notifications option must also be selected in the RISCO Cloud for the
notifications to be sent to the end-user’s smartphone. he Presence zone can also be muted
via the RISCO Cloud.
Sensitivity (Only for 2 Way PIR and 2 Way WatchOUT)
Defines the PIR sensitivity of the detector.
• Low
• Medium (2 Way WatchOUT)
• High
• Maximum (2 Way WatchOUT)
Camera Parameters (Only for 2 Way eyeWAVE PIR Cameras)