In a case of alarm, the following occurs:
⬧ In Away mode (Full Arm) the wireless siren will operate
⬧ In Disarm mode, only the buzzer on the main panel will operate
The Chime parameter is used as an audible indication to a zone violation while the
system is disarmed.:
Options:
• None
• Buzzer (Main panel)
• Chime Sound 1
• Chime Sound 2
• Chime Sound 3:
• Zone message: Not Applicable
Choose which zone will be supervised by the system receiver according to
the time defined under the timer RX Supervision. See page 32.
This option enables or disables the use of forced arming for each of the
system's zones, as follows:
⬧ If forced arming is enabled for a particular zone, it allows the system to
be armed even though this zone is faulty
⬧ When zone(s) enabled for forced arming are faulted, the LED blinks
during the disarm period
⬧ After arming, all zones enabled for forced arming are bypassed at the
end of the Exit Delay period
⬧ If a faulted zone (one enabled for force arming) is secured during the
armed period, it will no longer be bypassed and will be included among
the system's armed zones
Determines whether the zone participates in the No Activity function. The
No Activity function is for reception of signals used to monitor the activity
of sick, elderly or disabled people. See Timer "No Activity" on page 33.