Zones: Parameters
Parameter
Default
Range
Input Termination (IN 1):
NO
NO/NC/DEOL
Use this parameter to program the connection type used for each of the
system's zones.
N/O: Uses normally-open contacts and no terminating End-of-Line Resistor.
N/C: Uses normally-closed contacts and no terminating End-of-Line Resistor.
DEOL: Uses normally-closed (NC) contacts in a zone using two 10 KΩ of
End-of-Line Resistors to distinguish between alarms and tamper conditions.
Input Response Time
500
10500 ms
Set the duration for which a zone violation must exist in order for the zone to
trigger an alarm condition.
RWX73 F Parameters (Universal/Shutter mode)
The RWX73F is a 2-way multi-function supervised transmitter with two separate
channels that combines Magnetic/Door contact (universal or shutter).
The RWX73F has two reed switches for protection against opening doors and
windows, and against any attempt to tamper the detector using large magnets.
The RWX73F operates with RISCO Group 2-Way wireless systems
Alarm Hold
On
On
On/Off
Use this parameter to define the minimum period between alarm broadcasts.
ON: Only one alarm message is transmitted in any 2.5 minute time-period
OFF: Alarm detection is immediately transmitted
Input 2 Termination (External
Zone):
NO
NO/NC/DEOL
Use this parameter to program the connection type used for Input 2.
N/O: Uses normally-open contacts and no terminating End-of-Line Resistor.
N/C: Uses normally-closed contacts and no terminating End-of-Line Resistor.
DEOL: Uses normally-closed (NC) contacts in a zone using two 10 KΩ of
End-of-Line Resistors to distinguish between alarms and tamper conditions.
Shutter: Specifies that the Input 2 will count the number of open and close
pulses received. If the zone exceeds the predefined number of pulses, the
zone will be tripped and act according to its type definition. After a 25-
second timeout, the pulse counter is restarted. The pulse length is the
currently defined Loop Response time period.
Input 2 Response Time
500
10500 ms
Set the duration for which a zone violation must exist in order for the zone to
trigger an alarm condition.