3-8 Frame 3A and 3B Installation
PowerFlex® 700L Liquid-Cooled Drive User Manual
Publication 20L-UM001D-EN-P
Figure 3.7 Frame 3A and 3B Power Module Minimum Mounting Clearances
Verifying Power Module Input Ratings Match Supplied Power
It is important to verify that plant power will meet the input power
requirements of the PowerFlex 700L Liquid-Cooled drive’s Power Module
circuitry. See Appendix
A for input power rating specifications. Be sure
input power to the drive corresponds to the drive nameplate voltage and
frequency.
Equipment Lifting
This section explains how to lift the equipment.
Lifting the Complete Drive
For the complete drive equipment, always hoist the cabinet using the lifting
angles provided with the equipment (see Figure 3.8
). Prior to placing the
101.6 mm
(4.0 in.)
Cabinet Surface
101.6 mm
(4.0 in.)
50.8 mm
(2.0 in.)
152.4 mm
(6.0 in.)
152.4 mm
(6.0 in.)
Cabinet Surface
!
ATTENTION: To guard against possible personal injury and/or
equipment damage…
Do not allow any part of the drive or lifting mechanism to
make contact with electrically charged conductors or
components.
At no time should a person or their limbs be directly
underneath the items being lifted.
Do not subject the load to high rates of acceleration or
deceleration.
Inspect all lifting hardware for proper attachment before
lifting any drive unit.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rockwell Automation PowerFlex 700 and is the answer not in the manual?

Rockwell Automation PowerFlex 700 Specifications

General IconGeneral
BrandRockwell Automation
ModelPowerFlex 700
CategoryController
LanguageEnglish

Related product manuals