Signal Control and Signal Characteristics
R&S
®
SMW-K144
135User Manual 1178.8013.02 ─ 06
"Channel BW"
On the whole channel bandwidth.
"Per BWP"
By filtering the individual BWPs separately.
"Off"
Disbales filtering.
Remote command:
[:SOURce<hw>]:BB:NR5G:OUTPut:FBWP:STATe on page 257
Clipping Level
Sets the limit for clipping.
This value indicates at what point the signal is clipped. It is specified as a percentage,
relative to the highest level. 100% indicates that clipping does not take place.
Remote command:
[:SOURce<hw>]:BB:NR5G:OUTPut:CLEVel on page 258
Clipping Mode
Selects the clipping method. The dialog displays a graphical illustration on how this two
methods work.
"Vector | i + jq |"
The limit is related to the amplitude | i + q |. The I and Q components are mapped
together, the angle is retained.
"Scalar | i | , | q |"
The limit is related to the absolute maximum of all the I and Q values | i | + | q |.
The I and Q components are mapped separately, the angle changes.
Remote command:
[:SOURce<hw>]:BB:NR5G:OUTPut:CMODe on page 259
Sample Rate Mode
Sets how the sample rate is defined.
"FFT"
Sample rate is derived from the used FFT.
"Minimum"
Reserved for future use.
Remote command:
[:SOURce<hw>]:BB:NR5G:OUTPut:SAMRmode on page 257
Output
Indicates the baseband (BB) output.
Sample Rate
Indicates the sample rate value, calculated according to the selected Sample Rate
Mode, configured signal contents and several other settings, like the "Channel Band-
width" or "Deployment".
Remote command:
[:SOURce<hw>]:BB:NR5G:OUTPut:BBConf:ROW<ch0>:SRATe? on page 257
Conflict
A conflict is indicated if the "Sample Rate" and the "Playback Rate" are different.
[:SOURce<hw>]:BB:NR5G:OUTPut:BBConf:ROW<ch0>:CONFlict on page 257
Output Settings