Remote-Control Commands
R&S
®
SMW-K144
258User Manual 1178.8013.02 ─ 06
Parameters:
<Conflict> 0 | 1 | OFF | ON
*RST: 0
Example: See Example "Output settings" on page 162.
Manual operation: See "Conflict" on page 135
[:SOURce<hw>]:BB:NR5G:OUTPut:BBConf:ROW<ch0>:PBRate <PlaybackRate>
For [:SOURce<hw>]:BB:NR5G:OUTPut:BBConf:ROW<ch0>:VARiation 1, sets
the playback speed.
Parameters:
<PlaybackRate> integer
Per default, the playback rate is the same as the calculated
sample but the value range also depends on the installed
options.
Range: 400 to 5E8
*RST: 400
Example: See Example "Output settings" on page 162.
Manual operation: See "Playback Rate" on page 136
[:SOURce<hw>]:BB:NR5G:OUTPut:BBConf:ROW<ch0>:VARiation
<SRateVariation>
Activates sample rate variation.
Parameters:
<SRateVariation> 0 | 1 | OFF | ON
*RST: 0
Example: See Example "Output settings" on page 162.
Manual operation: See "Sample Rate Variation" on page 136
[:SOURce<hw>]:BB:NR5G:OUTPut:CLEVel <ClippingLevel>
Sets the limit for level clipping.
Parameters:
<ClippingLevel> integer
Range: 1 to 100
*RST: 100
Example: See Example "Output settings" on page 162.
Manual operation: See "Clipping Level" on page 135
Output Commands