Remote-Control Commands
R&S
®
SMW-K144
176User Manual 1178.8013.02 ─ 06
[:SOURce<hw>]:BB:NR5G:NODE:CELL<ch0>:SSPBch<st0>:POWer <PbchPower>
[:SOURce<hw>]:BB:NR5G:NODE:CELL<ch0>:SSPBch<st0>:PSSPow
<PssPower>
[:SOURce<hw>]:BB:NR5G:NODE:CELL<ch0>:SSPBch<st0>:SSSPow
<SssPower>
Sets the power of the SSS/PSS/PBCH allocations relative to the power of the other
resource elements.
Parameters:
<SssPower> float
Range: -80.0 to 10.0
Increment: 0.01
*RST: 0.0
Example: See Example "Configuring the SS/PBCH" on page 149.
Manual operation: See "PSS/SSS Power" on page 40
[:SOURce<hw>]:BB:NR5G:NODE:CELL<ch0>:SSPBch<st0>:CCODing:STATe
<PbchChanCoding>
Enables PBCH channel coding.
Parameters:
<PbchChanCoding> 0 | 1 | OFF | ON
*RST: 1
Example: See Example "Configuring the SS/PBCH" on page 149.
Manual operation: See "Channel Coding" on page 46
[:SOURce<hw>]:BB:NR5G:NODE:CELL<ch0>:SSPBch<st0>:CCODing:DATA
<PbchDataSource>
Selects the PBCH data source.
Parameters:
<PbchDataSource> PN9 | PN11 | PN15 | PN16 | PN20 | PN21 | PN23 | PATTern |
DLISt | ZERO | ONE
*RST: PN9
Example: See Example "Configuring the SS/PBCH" on page 149.
Manual operation: See "Data Source" on page 46
[:SOURce<hw>]:BB:NR5G:NODE:CELL<ch0>:SSPBch<st0>:CCODing:DLISt
<DataList>
Selects an existing data list file from the default directory or from the specific directory.