Remote-Control Commands
R&S
®
SMW-K144
193User Manual 1178.8013.02 ─ 06
Example: See Example "Configuring the PDSCH incl. PTRS settings"
on page 153.
Manual operation: See "I_MCS_1/I_MCS_2/I_MCS_3" on page 61
[:SOURce<hw>]:BB:NR5G:UBWP:USER<ch0>:CELL<st0>:DL:BWP<dir0>:
PDSCh:DMTA:PTRS:RB0 <PtrsNrb0>
[:SOURce<hw>]:BB:NR5G:UBWP:USER<ch0>:CELL<st0>:DL:BWP<dir0>:
PDSCh:DMTA:PTRS:RB1 <PtrsNrb1>
[:SOURce<hw>]:BB:NR5G:UBWP:USER<ch0>:CELL<st0>:DL:BWP<dir0>:
PDSCh:DMTB:PTRS:RB0 <PtrsNrb0>
[:SOURce<hw>]:BB:NR5G:UBWP:USER<ch0>:CELL<st0>:DL:BWP<dir0>:
PDSCh:DMTB:PTRS:RB1 <PtrsNrb1>
Sets the threshold values NRB
I
with I = {0, 1}.
Parameters:
<PtrsNrb1> integer
Range: 1 to 276
*RST: 276
Example: See Example "Configuring the PDSCH incl. PTRS settings"
on page 153.
Manual operation: See "N_RB_1/N_RB_2" on page 61
[:SOURce<hw>]:BB:NR5G:UBWP:USER<ch0>:CELL<st0>:DL:BWP<dir0>:
PDSCh:SCRambling:STATe <PdschScrambling>
Sets if a data scrambling ID is used for the initialization of the generator of the PDSCH
scrambling sequence.
Parameters:
<PdschScrambling> 0 | 1 | OFF | ON
*RST: 0
Example: See Example "Configuring the PDSCH incl. PTRS settings"
on page 153.
Manual operation: See "Use PDSCH Scrambling ID" on page 61
[:SOURce<hw>]:BB:NR5G:UBWP:USER<ch0>:CELL<st0>:DL:BWP<dir0>:
PDSCh:DSID <DataScrambleId>
If [:SOURce<hw>]:BB:NR5G:UBWP:USER<ch0>:CELL<st0>:DL:BWP<dir0>:
PDSCh:SCRambling:STATe1, sets the data scrambling ID.
Parameters:
<DataScrambleId> integer
Range: 0 to 1023
*RST: 0