Remote-Control Commands
R&S
®
SMW-K144
241User Manual 1178.8013.02 ─ 06
Parameters:
<FreqHopFlag> 0 | 1 | OFF | ON
*RST: 0
Example: See Example "Configuring the CORESET settings"
on page 157.
Manual operation: See "DCI Format 0_0" on page 109
[:SOURce<hw>]:BB:NR5G:SCHed:CELL<ch0>:SUBF<st0>:USER<dir0>:
BWPart<gr0>:ALLoc<user0>:CS:DCI<s2us0>:TB1:MCS <MCSTB1>
[:SOURce<hw>]:BB:NR5G:SCHed:CELL<ch0>:SUBF<st0>:USER<dir0>:
BWPart<gr0>:ALLoc<user0>:CS:DCI<s2us0>:TB2:MCS <MCSTB2>
Sets the DCI field modulation and coding scheme per transport block (TB).
Parameters:
<MCSTB2> integer
Range: 0 to 31
*RST: 0
Example: See Example "Configuring the CORESET settings"
on page 157.
Manual operation: See "DCI Format 0_0" on page 109
See "DCI Format 1_1" on page 113
[:SOURce<hw>]:BB:NR5G:SCHed:CELL<ch0>:SUBF<st0>:USER<dir0>:
BWPart<gr0>:ALLoc<user0>:CS:DCI<s2us0>:TB1:NDI <NDITB1>
[:SOURce<hw>]:BB:NR5G:SCHed:CELL<ch0>:SUBF<st0>:USER<dir0>:
BWPart<gr0>:ALLoc<user0>:CS:DCI<s2us0>:TB2:NDI <NDITB2>
Sets the DCI field new data indicator per transport block (TB).
Parameters:
<NDITB2> 0 | 1 | OFF | ON
*RST: 0
Example: See Example "Configuring the CORESET settings"
on page 157.
Manual operation: See "DCI Format 0_0" on page 109
See "DCI Format 1_1" on page 113
[:SOURce<hw>]:BB:NR5G:SCHed:CELL<ch0>:SUBF<st0>:USER<dir0>:
BWPart<gr0>:ALLoc<user0>:CS:DCI<s2us0>:TB1:RV <RVTB1>
[:SOURce<hw>]:BB:NR5G:SCHed:CELL<ch0>:SUBF<st0>:USER<dir0>:
BWPart<gr0>:ALLoc<user0>:CS:DCI<s2us0>:TB2:RV <RVTB2>
Sets the DCI field redundancy version per transport block (TB).