Remote-Control Commands
R&S
®
SMW-K144
245User Manual 1178.8013.02 ─ 06
Example: See Example "Configuring the CORESET settings"
on page 157.
Manual operation: See "DCI Format 0_0" on page 109
See "DCI Format 0_1" on page 110
[:SOURce<hw>]:BB:NR5G:SCHed:CELL<ch0>:SUBF<st0>:USER<dir0>:
BWPart<gr0>:ALLoc<user0>:CS:DCI<s2us0>:TPUCch <TpcPucch>
Sets the DCI field TPC command for scheduling PUCCH.
Parameters:
<TpcPucch> integer
Range: 0 to 3
*RST: 0
Example: See Example "Configuring the CORESET settings"
on page 157.
Manual operation: See "DCI Format 1_0" on page 112
See "DCI Format 1_1" on page 113
[:SOURce<hw>]:BB:NR5G:SCHed:CELL<ch0>:SUBF<st0>:USER<dir0>:
BWPart<gr0>:ALLoc<user0>:CS:DCI<s2us0>:PUCResind <PucchResInd>
Sets the DCI field PUCCH resource indicator.
Parameters:
<PucchResInd> integer
Range: 0 to 7
*RST: 0
Example: See Example "Configuring the CORESET settings"
on page 157.
Manual operation: See "DCI Format 1_0" on page 112
See "DCI Format 1_1" on page 113
[:SOURce<hw>]:BB:NR5G:SCHed:CELL<ch0>:SUBF<st0>:USER<dir0>:
BWPart<gr0>:ALLoc<user0>:CS:DCI<s2us0>:PDSHarq <PdschToHarq>
Sets the DCI field PDSCH-to-HARQ feedback timing Indicator.
Parameters:
<PdschToHarq> integer
Range: 0 to 7
*RST: 0
Example: See Example "Configuring the CORESET settings"
on page 157.
Manual operation: See "DCI Format 1_0" on page 112
See "DCI Format 1_1" on page 113
CORESET Commands