1-21
Section Tab Screen
The [SECTION] Tab Screen is used for manual sectioning, where selecting the SECTION tab displays the
current setting information and setting buttons needed to perform manual sectioning.
The SECTION Tab covers three primary temperature setting modes.
The "FREE Mode" screen lets you change the chamber temperature/specimen head temperature freely,
while the "Temperature Setting 1 Mode/Temperature Setting 2 Mode" screen lets you use a preset chamber
temperature/specimen head temperature. Press the "Temperature Setting Mode Change Button" to switch
among the modes.
FREE Mode Screen
In the FREE mode, you can change the setpoint chamber temperature/specimen head temperature and
section thickness freely. Refer to p. 1-32 for information on how to change the settings.
Chamber temperature setting button
Press this button to change the temperature in the chamber. The new temperature will also apply during
motorized sectioning. Refer to p. 1-32 for details.
Specimen head temperature setting button
Press this button to change the temperature of the specimen head. The new temperature will also apply
during motorized sectioning. Refer to p. 1-32 for details.
Temperature setting mode change button
Press this button to select and switch to the "Temperature Setting 1," "Temperature Setting 2" or "FREE"
mode.
Section thickness setting button
Press this button to change the section thickness to be used when sectioning. Refer to p. 1-30 for
details.
Chamber temperature
setting button
Current chamber temperature
Specimen head temperature setting button
Current specimen head
temperature
* The button blinks if the setpoint
temperature (±3°C) is not yet reached.
Temperature setting
mode change button
* The icon corresponding
to th
e currently selected
mode is displayed.
Section thickness setting
button
Currently set section
thickness (
μm)
Current specimen head position (
μ
m)
* "0" indicates the home position.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sakura Tissue-Tek Polar DM and is the answer not in the manual?

Sakura Tissue-Tek Polar DM Specifications

General IconGeneral
BrandSakura
ModelTissue-Tek Polar DM
CategoryMedical Equipment
LanguageEnglish

Related product manuals