ii Close and Reclose Logic Date Code 990215
SEL-351P Manual Técnico
Factory Settings Example ...........................................................................................6-23
Additional Settings Example 1 ...................................................................................
6-23
Additional Settings Example 2 ...................................................................................
6-23
Additional Settings Example 3 ...................................................................................
6-24
Other Settings Considerations.....................................................................................
6-24
Block Reset Timing Setting (79BRS).................................................................................
6-24
Example 1....................................................................................................................
6-25
Sequence Coordination Setting (79SEQ) ...........................................................................
6-25
Reclose Supervision Setting (79CLS) ................................................................................
6-26
TABLES
Table 6.1: Relay Word Bit and Front-Panel Correspondence to Reclosing Relay States......................6-12
Table 6.2: Reclosing Relay Timer Settings and Setting Ranges ............................................................
6-15
Table 6.3: Shot Counter Correspondence to Relay Word Bits and Open Interval Times......................
6-18
Table 6.4: Reclosing Relay SEL
OGIC
Control Equation Settings ..........................................................6-18
Table 6.5: Open Interval Time Example Settings...................................................................................
6-23
FIGURES
Figure 6.1: Close Logic .............................................................................................................................6-2
Figure 6.2: Reclose Supervision Logic (following open interval time-out)..............................................
6-5
Figure 6.3: Reclose Supervision Limit Timer Operation (refer to bottom of Figure 6.2).........................
6-6
Figure 6.4: SEL-351P Recloser Controls Installed at Both Ends of a Transmission Line in a
High-Speed Reclose Scheme .........................................................................................
6-9
Figure 6.5: Reclosing Relay States and General Operation ....................................................................
6-12
Figure 6.6: Reclosing Sequence from Reset to Lockout with Example Settings ....................................
6-16
Figure 6.7: Reclose Blocking for Islanded Generator .............................................................................
6-24
Figure 6.8: SEL-351P Recloser Controls in Series, Requiring Sequence Coordination.........................
6-26

Table of Contents