Process data description
MOVIPRO® ADC process sequence
Manual – MOVIPRO
®
with EtherNet/IP™ or Modbus/TCP Fieldbus Interface
130
Configuring CCU application module
A CCU application module is commissioned as an axis in the Application Configurator
controller software.
Proceed as follows:
1. Start the Application Configurator and create a new configuration.
2. Insert a single axis into the configuration. Click on the symbol [1].
18150922123
ð A new line is displayed in the axis area.
3. Specify the following settings for the axis:
Window element Setting/value
Name Name of the axis
Controller interface SBUS_1
Axis address 20
Device type MOVIPRO LT
Application module
Desired application module with the
matching process data profile
4. Click the button [2].
ð After successful configuration, a green check mark appears at the end of the line.
ð In this example, the "Transparent 6PD" CCU application module is configured.
16998413/EN – 12/2016