EasyManua.ls Logo

SEW-Eurodrive MOVIPRO Ethernet/IP - Page 251

SEW-Eurodrive MOVIPRO Ethernet/IP
280 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14
Service
List of power section errors
Manual – MOVIPRO
®
with EtherNet/IP™ or Modbus/TCP Fieldbus Interface
251
Code Meaning Response
(P)
Sub-
code
Meaning Possible cause Measure
14 Encoder Immediate
stop
32 HIPERFACE
®
en-
coder on motor
encoder reports
an error
Encoder cable or
shield not connec-
ted correctly
Short circuit/wire
break in encoder
cable
Encoder defective
Check encoder cable
and shield for correct
connection, short cir-
cuit and wire breaks.
33 HIPERFACE
®
en-
coder on external
encoder reports
an error
34 Encoder fault mo-
tor encoder re-
solver
Encoder connec-
tion or encoder is
defective
17 System
error
Immediate
stop
0 "Stack overflow"
error
Inverter electronics
disrupted, possibly
due to EMC influences
Check grounding
and shielding and
improve, if neces-
sary
Contact
SEW‑EURODRIVE
Service if the error
reoccurs
18 0 "Stack underflow"
error
19 0 "External NMI"
error
20 0 "Undefined op-
code" error
21 0 "Protection fault"
error
22 0 "Illegal word op-
erand access"
error
23 0 "Illegal instruction
access" error
24 0 "Illegal external
bus access" error
16998413/EN – 12/2016