14
Service
List of power section errors
Manual – MOVIPRO
®
with EtherNet/IP™ or Modbus/TCP Fieldbus Interface
259
Code Meaning Response
(P)
Sub-
code
Meaning Possible cause Measure
94 EE-ROM
checksum
Immediate
stop
0 Power section
parameters
Inverter electronics
disrupted, possibly
due to effect of EMC
influence or a defect.
Send the device to
SEW‑EURODRIVE for
repair.
5 Control unit data
6 Power section
data
7 Invalid version of
the configuration
data set
97 Copy error Immediate
stop
0 Parameter set
upload is/was
faulty
Error during data
transmission
Memory can
neither be written
nor read
Repeat copying
process
Restore delivery
state (P802) and
repeat copying
process
1 Parameter set
download to
device cancelled
2 Not possible to
adopt parameters
98 CRC error Immediate
stop
0 "CRC via internal
flash" error
Internal device fault
Flash memory defect-
ive
Send the device to
SEW‑EURODRIVE for
repair.
99 IPOS
®
ramp cal-
culation
Immediate
stop
0 "Ramp calcula-
tion" error
Only in IPOS
plus®
op-
erating mode:
Positioning ramp is si-
nusoidal or square and
an attempt is made to
change ramp times
and traveling velocities
with enabled inverter.
Rewrite the IPOS
plus®
program so that ramp
times and traveling ve-
locities can only be
altered when the in-
verter is inhibited.
100 Vibration
warning
Display
error (P)
0 Vibrations dia-
gnostics warning
Vibration sensor warn-
ing (see "DUV10A" op-
erating instructions)
Determine cause
of vibrations
Continue operation
until F101 occurs
101 Vibration
error
Rapid stop
(P)
0 Vibration dia-
gnostics error
Vibration sensor sig-
nals fault
SEW‑EURODRIVE re-
commends that you
remedy the cause of
the vibrations immedi-
ately.
102 Oil aging
warning
Display
error (P)
0 Oil aging warning Warning signal from
the oil aging sensor.
Schedule oil change
103 Oil aging
error
Display
error (P)
0 Oil aging error Error message from
the oil aging sensor.
SEW‑EURODRIVE re-
commends that you
change the gear unit
oil immediately.
104 Oil aging
overtem-
perature
Display
error (P)
0 Oil aging over-
temperature
Overtemperature sig-
nal from the oil aging
sensor.
Let oil cool down
Check if the gear
unit cools properly
16998413/EN – 12/2016

Table of Contents

Related product manuals