14
Service
List of power section errors
Manual – MOVIPRO
®
with EtherNet/IP™ or Modbus/TCP Fieldbus Interface
260
Code Meaning Response
(P)
Sub-
code
Meaning Possible cause Measure
105 Oil aging
ready sig-
nal
Display
error (P)
0 Oil aging ready
signal
Oil aging sensor is not
ready for operation
Check voltage sup-
ply of oil aging
sensor
Check and, if ne-
cessary, replace
the oil aging
sensor
106 Brake wear Display
error (P)
0 Brake wear Brake lining worn
down
Replace brake lining
(see operating instruc-
tions of the motor)
110 Fault
"Ex-e pro-
tection"
Emergency
stop
0 Duration of oper-
ation below 5Hz
exceeded
Duration of operation
below 5Hz exceeded
Check configura-
tion
Shorten duration of
operation below
5Hz