14
Service
List of power section errors
Manual – MOVIPRO
®
with EtherNet/IP™ or Modbus/TCP Fieldbus Interface
263
Code Meaning Response
(P)
Sub-
code
Meaning Possible cause Measure
122 Absolute
encoder
Immediate
stop
60 Hiperface
®
en-
coder: Analog
voltages not
within tolerance
61 Hiperface
®
en-
coder: Critical
transmitter cur-
rent
Dirt
Transmitter broken
Replace the encoder.
62 Hiperface
®
en-
coder: Critical en-
coder temperat-
ure
Replace the encoder.
63 Hiperface
®
en-
coder: Position
error
Speed too high, posi-
tion cannot be created
Reduce the speed.
122 Absolute
encoder
Immediate
stop
64 HIPERFACE
®
en-
coder: internal
encoder fault
Replace the encoder.
65
66
67
122 Absolute
encoder
Immediate
stop
256 SSI encoder:
Voltage dip
Drop in DC 12V sup-
ply voltage
Check the supply
voltage of the encoder.
257 SSI encoder: In-
terrupted clock or
data line
Check connection to
encoder.
258 SSI encoder:
Change of posi-
tion
122 Absolute
encoder
Immediate
stop
259 SSI encoder: In-
sufficient clock
frequency
Increase clock fre-
quency.
260 SSI encoder: En-
coder signals
programmable
error
Check the encoder
parameterization.
261 SSI encoder: no
high level avail-
able
Replace the en-
coder.
Contact the
SEW‑EURODRIVE
Service.
16998413/EN – 12/2016