List of power section errors
Manual – MOVIPRO
®
with EtherNet/IP™ or Modbus/TCP Fieldbus Interface
262
Code Meaning Response
(P)
Sub-
code
Meaning Possible cause Measure
122 Absolute
encoder
Immediate
stop
1 Plausibility check Check to cables of the
sine tracks or replace
the encoder.
2 Hiperface
®
en-
coder: Unknown
encoder type
3 Hiperface
®
en-
coder: Corrupt
encoder name-
plate data
32 HIPERFACE
®
en-
coder: internal
encoder fault
Replace the encoder.
33 Hiperface
®
en-
coder: Analog
voltages not
within tolerance
122 Absolute
encoder
Immediate
stop
34 HIPERFACE
®
en-
coder: internal
encoder fault
Replace the encoder.
35
36
37
38
39
40
122 Absolute
encoder
Immediate
stop
41 Hiperface
®
en-
coder: Commu-
nication error
Device and
HIPERFACE
®
encoder
connection interrupted
Check the wiring.
42
43
44
45
122 Absolute
encoder
Immediate
stop
46 HIPERFACE
®
en-
coder: internal
encoder fault
Replace the encoder.
47
48
49
50