5
Installation notes
Connection to the Ethernet network
Manual – MOVIPRO
®
with EtherNet/IP™ or Modbus/TCP Fieldbus Interface
32
• X4232_12 (RJ45 connector)
• X4233_11 (M12 connector)
• X4233_12 (M12 connector)
To connect the device to the Ethernet, connect one of the Ethernet interfaces to the
other network node using a category 5, class D twisted-pair cable in accordance with
IEC11801, edition 2.0.
INFORMATION
According to IEEE 802.3, 200 Edition, the maximum cable length for
10 MBaud/100 MBaud Ethernet (10BaseT/100BaseT) between 2 network nodes is
100m.
X4232_11, X4232_12: Ethernet interface
The following table provides information on this connection:
Function
• EtherNet/IP™ interface
• Modbus/TCP interface
Connection type
Push-pull RJ45
Wiring diagram
Assignment
No. Name Function
1 TX+ Transmit line (+)
2 TX- Transmit line (-)
3 RX+ Receive line (+)
4 Res. Reserved
5 Res. Reserved
6 RX- Receive line (-)
7 Res. Reserved
8 Res. Reserved
16998413/EN – 12/2016