5
Installation notes
Connection to the Ethernet network
Manual – MOVIPRO
®
with EtherNet/IP™ or Modbus/TCP Fieldbus Interface
36
Code Meaning Possible cause Measure
OFL Internal communication error While backing up data or
restoring a data backup:
Wait a few minutes until the
display changes.
In normal operation:
• Disconnect the device
from the AC 400V supply
and the DC24V supply
voltage for at least 30s.
• Restart the device.
run The connection has been es-
tablished successfully. The
statuses of the components
or the application are dis-
played after 3 s.
SF1 Communication error with the
power section
• Parameter channel 2 not
activated (P889)
• Manual operation not fin-
ished
• Parameter lock power
section activated (P803)
• Configuration in the Ap-
plication Configurator not
completed or not com-
pletely loaded
• Activate parameter chan-
nel 2
• Activate and deactivate
manual mode
• Disconnect the device
from the AC 400V supply
and the DC 24V supply
voltage for at least 30s.
• Restart the device.
SF2 Error in external periphery Check the cabling of the di-
gital inputs and outputs as
well as the connections of the
communication package.
SF3 Error while loading the applic-
ation module
Non-enabled application
module loaded
• Set parameter P802
"Factory setting" of the
"PFA-..." power section to
"Delivery state".
• Load an enabled applica-
tion module into the
"PFA-..." power section
SF10 Error during configuration
with the Application Configur-
ator
Configuration with Application
Configurator not completed
Complete the configuration
with the Application Configur-
ator. Load it into the device.
SF20 Error during data backup,
data backup on SD memory
card failed
Start data backup again.
SF21 Error during data backup,
data backup on SD memory
card failed
SD memory card is write pro-
tected
Remove write protection from
SD memory card.
SF22 Error during data recovery,
data recovery to device failed
Start data restoring again.
16998413/EN – 12/2016