6
Configuration and startup of EtherNet/IP™
Project planning examples
Manual – MOVIPRO
®
with EtherNet/IP™ or Modbus/TCP Fieldbus Interface
57
14. Check if the process data correspond to the values that are displayed in the para-
meter tree of the engineering software MOVITOOLS
®
MotionStudio.
17894369291
ð When you move the mouse over the parameter, the tooltip shows the index,
subindex, factor, etc. of the parameter.
Writing parameters
Proceed as follows:
1. Create the user-defined data type "SEW_Parameter_Channel". It allows you to or-
ganize the process data in a structure and simplifies access to the data elements.
INFORMATION
To ensure proper operation of the parameter channel, do not change the order of the
variables. The data types must also match the figure.
9007214912527883
2. Create the following controller tags:
Name Data structure
WriteParameter MESSAGE
WriteParameterRequest SEW_Parameter_Channel
16998413/EN – 12/2016