7
Ethernet Industrial Protocol (EtherNet/IP™)
CIP object directory
Manual – MOVIPRO
®
with EtherNet/IP™ or Modbus/TCP Fieldbus Interface
84
7.4.8 EtherNet link object
• Contains information on the Ethernet communication interface.
• Class code: F6
hex
Class
Attrib-
ute
Ac-
cess
Name Data type Default value
hex
Description
1 Get Revision UINT 0001 Revision1
2 Get Max Instance UINT 0002 Maximum instance
3 Get
Number of
Instances
UINT 0002
The device has two TCP/IP inter-
faces.
Instance 1–Ethernet connection X4232_1/X4233_1
The following table provides an overview via instance 1 of the identity object:
Attrib-
ute
Ac-
cess
Name Data type Default value
hex
Description
1 Get Interface Speed UDINT 00000064 Transmission speed in MBit/s
Standard value = 100
2 Get Interface Flags DWORD – • Bit 0: Displays the active link.
• Bit 1: Displays full duplex mode.
• Bit 2–4: Signals negotiation
state.
• Bit 5: Displays whether the
manual setting has to be reset.
• Bit 6: Indicates a local hardware
error.
3 Get Physical Address ARRAY of 6 US-
INTs
00 0F 69
xxxx xx
MAC ID
SEW MAC OUI: 00 0F 69
Instance 2–Ethernet connection X4232_2/X4233_22
The following table provides an overview via instance 2 of the identity object:
Attrib-
ute
Ac-
cess
Name Data type Default value
hex
Description
1 Get Interface Speed UDINT 00000064 Transmission speed in MBit/s
Standard value = 100
2 Get Interface Flags DWORD – • Bit 0: Displays the active link.
• Bit 1: Displays full duplex mode.
• Bit 2–4: Signals negotiation
state.
• Bit 5: Displays whether the
manual setting has to be reset.
• Bit 6: Indicates a local hardware
error.
3 Get Physical Address ARRAY of 6 US-
INTs
00 0F 69
xxxx xx
MAC ID
SEW MAC OUI: 00 0F 69
Supported services
The following table shows the services supported by the Ethernet link object:
Service Code
hex
Service Name Instance attribute 1 Instance attribute 2
01 Get_Attributes_All X –
0E Get_Attribute_Single X X
16998413/EN – 12/2016