Chapter 8 Operating Instructions
CLV 45x Bar Code Scanner
8-10
©
SICK AG · Division Auto Ident · Germany · All rights reserved 8 009 139/K949/06-06-2002
Troubleshooting
1. The "Result" LED does not
light up at the end of the rea-
ding pulse.
(Default setting: "Good
Read")
Continued
At dynamic focal position
changeover:
Trigger source parameterized
incorrectly
Continued
The bar code is tilted strongly
with respect to the scan line
(large tilt)
The reading angles at which
the bar code appears to the
CLV are too large
Bar code is in total reflection
zone
b) Trigger source: "Serial
interface":
Check the data connection to
the host.
Use the CLV-Setup user inter-
face to check the host com-
mand strings: Select the
T
ERMINAL
INTERFACE
tab card.
Select the M
ONITOR
HOST
INTERFACE
function (refer to
Chapter 6.5.7 Host interface
monitoring, Page 6-26).
Download temporarily to CLV!
c) Trigger source: "Timer":
Check the changeover time
setting.
Select CLV-Setup user inter-
face: C
ODE
CONFIGURATION
tab
card, D
ECODER
section. Select
the SMART decoder.
Download to CLV!
Select CLV-Setup user inter-
face: C
ODE
CONFIGURATION
tab
card, D
ECODER
section.
Select the standard decoder.
Download temporarily to the
CLV!
Call up P
ERCENTAGE
EVALUA
-
TION
, select distance configu-
ration.
Monitor reading quality
(reading quality > 70 %!).
If necessary, realign CLV and/
or reconfigure the distance
configuration.
If "OK", choose SMART
decoder. Download to the
CLV!
Optimize CLV alignment
(scan line should strike the
bar code at an angle of ap-
prox. 15
°
)
Check the reading quality
with the CLV-Setup user inter-
face. Call up P
ERCENTAGE
EVALUATION
(refer to
Chapter 6.5.2 Percentage
evaluation, Page 6-21)
Fault Possible cause Remedy
Table 8-5: Troubleshooting: Result output errors in Reading mode