Operating instructions Chapter 11
S300
8010948/YY96/2016-02-17 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 111
Subject to change without notice
Diagnostics
Display Possible cause Rectification of the error
Waiting for valid input
signals
The indication extinguishes automatically if
an input signal is present that corresponds
to the configured evaluation type (1-of-n or
complementary).
If the display does not go off:
Check the wiring.
Check the control signals for correct
switching behavior.
Check, if velocity ranges are used for moni-
toring case switching, whether the EFI status
information Speed valid is transferred (see
Tab. 37 on page 131).
Check the system configuration with the aid
of the CDS. Transfer the corrected configu-
ration to the S300 again.
Waiting for
configuration or
configuration not
completed
The display goes off automatically once the
configuration has been successfully trans-
ferred.
If the display does not go off:
Check the system configuration with the aid
of the CDS. Transfer the corrected configu-
ration to the S300 again.
Check whether the configuration saved in
the system plug is compatible with the S300
(see 10.3 on page 106).
Waiting for restart of
the device
Switch off the voltage supply for the S300
for at least 2 seconds and then switch it
back on.
or
Error of the external
device monitoring
(EDM)
Check whether the contactors are working
correctly or if they are wired incorrectly and
rectify any error.
If is displayed: also switch off the voltage
supply for the S300 for at least 2 seconds
and switch it back on.
Error in the control
switch for restart or
reset
Check the functionality of the control switch.
The button may be defective or permanently
operated.
Check the wiring of the control switch for
short-circuit to 24 V.
Velocity tolerance
exceeded: The diffe-
rence between the
velocities measured by
the incremental enco-
ders is too large.
Check the incremental encoders.
Check the configuration of the incremental
encoder inputs with the aid of the CDS.