Chapter 11 Operating instructions
S300
112 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 8010948/YY96/2016-02-17
Subject to change without notice
Diagnostics
Display Possible cause Rectification of the error
Direction of movement
output by the incre-
mental encoders is
different
Check the wiring of the incremental encoder
inputs, e.g. for incorrect pin assignments.
Maximum frequency at
input INC1 exceeded
Maximum frequency at
input INC2 exceeded
Check the function of the incremental
encoders.
Check the configuration of the incremental
e
ncoder inputs with the aid of the CDS.
Check whether the permitted maximum
velocity of the vehicle is exceeded!
S300 faulty
Configuration memory
in the system plug
faulty
Switch off the voltage supply for the S300
for at least 2 seconds and then switch it
back on.
If the display does not go off:
Send the S300 or the system plug to the
manufacturer for repair.
A second device which
is connected via EFI is
faulty.
Check the connected device and the
connection.
Overcurrent on OSSD
connection 1
Check the switching element connected
(contactor, relay). Replace, if necessary.
Check the wiring for short-circuit to 0 V.
Short-circuit to 24 V at
OSSD connection 1
Check the wiring for short-circuit to 24 V.
Short-circuit to 0 V at
OSSD connection 1
Check the wiring for short-circuit to 0 V.
Overcurrent on OSSD
connection 2
Check the switching element connected
(contactor, relay). Replace, if necessary.
Check the wiring for short-circuit to 0 V.
Short-circuit to 24 V at
OSSD connection 2
Check the wiring for short-circuit to 24 V.
Short-circuit to 0 V at
OSSD connection 2
Check the wiring for short-circuit to 0 V.
Short-circuit between
OSSD connection 1
and 2
Check the wiring and rectify the error.
General OSSD wiring
error
Check the complete wiring of the OSSDs.
Device is addressed as
guest
No error. The symbol is displayed for approx. 2
seconds on switching on a device that is
addressed as a guest.
Device is addressed as
host
No error. The symbol is displayed for approx. 2
seconds on switching on a device that is
addressed as a host.