Chapter 4 Operating instructions
S300
44 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 8010948/YY96/2016-02-17
Subject to change without notice
Configurable functions
If the protective field or the warning fields stretch as far as a wall or another object
(pillar, neighboring machine, shelf), there should be a distance of 100 mm between the
protective field or warning field and the object to prevent false triggering .
WARNING
Secure unprotected areas!
If it is possible to access a narrow strip between the protective field and a wall or another
object, you must protect this strip using additional measures (e.g. fence or floor protec-
tion).
Note
Fig.
19
:
Configuring protec
-
tive field and warning field

Table of Contents

Other manuals for SICK S300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK S300 and is the answer not in the manual?

SICK S300 Specifications

General IconGeneral
Protection ClassIP65
Resolution30 mm
InterfaceRS-422, Ethernet
Power Supply24 V DC
Operating Temperature0 °C ... +50 °C