EasyManua.ls Logo

SICK S300

SICK S300
148 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating instructions Chapter 4
S300
8010948/YY96/2016-02-17 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 49
Subject to change without notice
Configurable functions
Static complementary sampling
Using the two control input pairs on the S300 Advanced 2
2
= 4 monitoring cases can be
s
witched, using the three control input pairs on the S300 Professional and Expert 2
3
=
8
monitoring cases can be switched.
Using external inputs (e.g. those of a Flexi Soft safety controller, see section 4.5 “Inputs”
on page 37), 2
5
= 32 monitoring cases can be switched via maximally five control input
pairs.
A B C D E E.g. case
0 0 0 0 0 1
1 0 0 0 0 2
0 1 0 0 0 3
1 1 0 0 0 4
0 0 1 0 0 5
1 0 1 1 0 6
0 1 1 0 0 7
1 1 1 0 0 8
0 1 1 1 0 15
1 1 1 1 0 16
0 0 0 0 1 17
0 1 1 1 1 31
1 1 1 1 1 32
Undefined input information will result in the S300 switching the OSSDs to the OFF state
or signaling Protective field infringed via EFI.
Tab.
18
:
Truth table with
complementary evaluation
Note