E3G060 Control module ”monitored” (Part No 460514)
139
Building Technologies 001260_k_en_--.doc
Fire Safety & Security Products 02.2005
34 E3G060 Control module ”monitored” (Part No 460514)
34.1 Overview
z Control module for monitored alarm devices
z 6 monitored control lines 24 V, 2 A with EMI and over voltage protection
z Individual allocation of control lines via maintenance PC (AlgoWorks)
z It is possible to specify separately whether or not each line must be activated in
”Emergency alarm” mode
z Card format 100 mm x 200 mm
z I-Bus address is set at programming switch ”S3
34.2 Application
the E3G060 module is required in systems with more than 2 monitored control
lines for alarm / or similar equipment
the current on one control line may not exceed 2 A; however, the total current for
all 6 control lines may not exceed 4 A
34.3 Key data
Control outputs number
max. load
termination resistor
6
2 A each at 24...29.6 V
4.75 k
Quiescent current at 24 V 25 mA (no control line active)
Terminal block X1 (20 terminals)
mounted on module chassis
for the connection of the prefabricated cable to connection level, or
for direct connection of the periphery