Determining the components of the FC2080
12
177 |
Building Technologies
12.4 Determining the components of the FC2080
Use the information in this chapter to determine the specific components for the fire
control panel FC2080. These details are required to determine the power supplies
and batteries. Other components that can be installed can be seen at the compact
stations.
Use Required components Notes
Processor unit
● Processor unit (19", FC2080) FCC2002-
A1
Basic component, contains:
● Card cage (CPU)
● One ↑ CPU card (FC2080)
● Once communication card
(FC2080)
● Card cage (5 slots)
Redundant CPU operation ● Second CPU card (FC2080)
The network module (SAFEDLINK,
CC) of the communication card
must be installed on the second
CPU card.
Networking via FCnet
● Network module (SAFEDLINK, CC)
FN2010-A1 is already installed on the
first CPU card (FC2080)
Redundant networking via
FCnet
● Network module (SAFEDLINK, CC)
FN2010-A1 is already installed on the
communication card (FC2080)
FCnet networking over
larger distances
● Fiber optic cable network module (SM)
FN2006-A1 or
● Fiber optic cable network module (MM)
FN2007-A1
For optical FCnet over long
distances (up to 40 km).
● Repeater (SAFEDLINK) FN2002-A1
For FCnet extension, max. 1
repeater between 2 ↑ stations;
requires a supply of DC 9...30 V.
● Interface module DL485/13-xx-ST-SBT
For FCnet extension, max. 1
segment between 2 stations;
requires a supply of DC 9...30 V
per module.
↑ Extended networking via
FCnet/LAN or optical
Ethernet
● Ethernet switch (modular) FN2012-A1
Replaces FN2008-A1. Also
requires:
● Connection module (MoNet)
FCA2031-A1
● Ethernet module (MM)
VN2002-A1 or Ethernet
module (SM) VN2003-A1
● Mounting kit (switch) FCA2029
Remote transmission
connections and additional
horn outputs
● I/O card (RT) FCI2007-A1
In each case, this I/O card
provides a ↑ remote transmission
output alarm and fault and a horn
output for the fire control panel
FC2080.