Assembling the FC2080
Determining the batteries and power supply
12
188 | 242
Building Technologies
008843_v_en_
--
Fire Safety
2015
-
-
15
Operating currents, optional operating unit
Consumer Type I
R
[mA] I
A
[mA] Qty. I
R total
I
A total
Notes
Operating unit FCM20xx 120 200 No options
Fire terminal (Touch) FT2080 125 130 No options
Network module
(SAFEDLINK)
FN2001-A1 40 40
Always include in
calculations
LED indicator (internal) FTO2002-A1 4 70 Per LED indicator (internal)
EVAC-NL operating unit
[NL]
FTO2007-N1 6 30 10-zone EVAC
Operating add-on
(2xEVAC term.) [NL]
FCM2008-N1 12 60
Operating add-on for 20-
zone EVAC
EVAC-NL connector
board [NL]
FTI2002-N1 25 25 For remote EVAC
FBA terminal [CH] FTO2004-C1 4 50
Ethernet connection 15 15
With networking and
connection of external
printer via the Ethernet
RS232 module (isolated) FCA2001-A1 11 11 I
R
= no-load operation
I
A
= send/receive
RS485 module (isolated) FCA2002-A1 11 11
Event printer (built-in) FTO2001-A1 50…100
Min. 50 mA, depending on
frequency of printing
Optional operating add-on
1
FCM20xx Depending on components
Optional operating add-on
2
FCM20xx Depending on components
Total, operating unit
Quiescent current = I
R total
Alarm current = I
A total
__ __ __ __
Table 59: Operating currents, optional operating unit