8 Using the Data Record Interface
165
IE/ASINTERFACE LINK PN IO as of hardware version 1, as of firmware version V2.0
Release 08/2018
C79000G8976C21603
8.2.2.14 Read_I/O_Configuration
Meaning
With this call, the I/O configuration of an AS-i slave can be read out directly over
the AS-i cable. The call is intended for diagnostic purposes and is not required in
the normal master mode.
Structure of the RecordDataRead service Index 33
Byte Meaning
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
0 Version_hi = 0x00
1 Version_lo = 0x00
2
0x0 I/O configuration
3 Reserved 0x00