8.6 SYSTEM - "Start-up files" softkeys
Surface grinding
150 Programming and Operating Manual, 11/2012, 6FC5398-5CP10-3BA0
0DQXIDF
WXUHUGULYH
86%
GULYH
PDQX
DUFKLYH
Baud rate ... used to set the interface transmission rate.
300 baud
600 baud
1200 baud
2400 baud
4800 baud
9600 baud
19200 baud
38400 baud
57600 baud
115200 baud
Stop bits Number of stop bits with asynchronous transmission
Input:
1 stop bit (default setting)
2 stop bits
Parity Parity bits are used for error detection. These are added to the coded character to
convert the number of digits set to "1" into an odd or even number.
Input:
No parity (default setting)
Even parity
Odd parity
Data bits Number of data bits with asynchronous transmission
Input:
7 data bits
8 data bits (default)
Overwriting
with
confirmation
Y: When reading in, it is checked whether the file already exists in the NC.
N: The files are overwritten without confirmation warning.
Reading-in and reading-out data of the manufacturer's directory "F".
Reading-in and reading-out data of a USB FlashDrive.
Use this function to create/restore a commissioning archive on/from the system
CompactFlash Card.
No archive file has been created in the following display. The symbol for the zip archive
sends a signal with an exclamation mark.

Table of Contents

Other manuals for Siemens SINUMERIK 802D sl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 802D sl and is the answer not in the manual?

Siemens SINUMERIK 802D sl Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 802D sl
CategoryController
LanguageEnglish

Related product manuals