System
8.2 SYSTEM - "Start-up" softkeys
Surface grinding
Programming and Operating Manual, 11/2012, 6FC5398-5CP10-3BA0
115
6WDUWXS
1&
3/&
+0,
The NC and PLC data are backed up. The drive data are not backed up.
Note
Saved data can be called via the following operator action:
Press the <SELECT> key while the control system is booting.
In the setup menu, select "Reload saved user data".
Press the <Input> key
Note
Data that have been backed up can be called again from the operating area <SYSTEM> >
"Start-up" > "Power up with backed up data"!
8.2 SYSTEM - "Start-up" softkeys
Commissioning
Use this softkey to select the NC power-up mode.
Select the desired mode using the cursor.
Normal power-up
The system is restarted
Power-up with default data
The display machine data are reset to their standard values (restores the initial state
when originally supplied)
Power-up with backed up data
The system restarts with the data that were last backed up (see Backup data)
The PLC can be started in the following modes:
Restart
Memory reset
Furthermore, it is possible to link the start with a subsequent debugging mode.
Selects the power-up mode of the HMI.

Table of Contents

Other manuals for Siemens SINUMERIK 802D sl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 802D sl and is the answer not in the manual?

Siemens SINUMERIK 802D sl Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 802D sl
CategoryController
LanguageEnglish

Related product manuals