EasyManuals Logo

Siemens SINUMERIK 802D sl User Manual

Siemens SINUMERIK 802D sl
364 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #251 background imageLoading...
Page #251 background image
Programming
10.3 Axis movements
Surface grinding
Programming and Operating Manual, 11/2012, 6FC5398-5CP10-3BA0
251
System variable for status: $AA_FXS[
axis
]
This system variable provides the "Travel to fixed stop" status for the axis specified:
Value =
0: Axis not at fixed stop
1: Fixed stop successfully approached
(axis is in fixed-stop monitoring window)
2: Approach to fixed stop has failed (axis is not at fixed stop)
3: Travel to fixed stop activated
4: Fixed stop detected
5: Travel to fixed stop is deselected. The deselection is not yet completed.
Query of the system variable in the part program initiates a preprocessing stop.
For SINUMERIK 802D sl, only the static states can be detected before and after
selection/deselection.
Alarm suppression
The issuing of the following alarms can be suppressed with machine data:
20091 "Fixed stop not reached"
20094 "Fixed stop aborted"
References: "Description of Functions", Section "Travel to fixed stop"

Table of Contents

Other manuals for Siemens SINUMERIK 802D sl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 802D sl and is the answer not in the manual?

Siemens SINUMERIK 802D sl Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 802D sl
CategoryController
LanguageEnglish

Related product manuals