251
System variable for status: $AA_FXS[
axis
]
This system variable provides the "Travel to fixed stop" status for the axis specified:
Value =
0: Axis not at fixed stop
1: Fixed stop successfully approached
(axis is in fixed-stop monitoring window)
2: Approach to fixed stop has failed (axis is not at fixed stop)
3: Travel to fixed stop activated
4: Fixed stop detected
5: Travel to fixed stop is deselected. The deselection is not yet completed.
Query of the system variable in the part program initiates a preprocessing stop.
For SINUMERIK 802D sl, only the static states can be detected before and after
selection/deselection.
Alarm suppression
The issuing of the following alarms can be suppressed with machine data:
20091 "Fixed stop not reached"
20094 "Fixed stop aborted"
References: "Description of Functions", Section "Travel to fixed stop"