List of the INI Files
A.2 AEDITOR.INI
HMI Advanced (IM4)
276 Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
; default mode for checking of readonly blocks, 0: no check,
; else check for readonly
ReadOnlyCheck=1
HiddenCheck=1
; default text for identification of readonly blocks
TextForReadOnlyCheck=;*RO*
TextForHiddenCheck=;*HD*
[MMC_Wizard]
Aeditor=Aeditor.com
A new line is inserted by pressing the <Return> key:
NewLineInStepMode
=0 (Default)
If HiddenCheck=TRUE, whereby certain lines are hidden, <Return> can only
be used at the end of the step (after the hidden lines).
If HiddenCheck=FALSE, whereby all the lines are shown, <Return> can be
used within a step.
=1 Although HiddenCheck=FALSE, <Return> can only be used at the beginning
or end of a step (i.e. it cannot be used within a step).
=2 Irrespective of the value for HiddenCheck, <Return> can only be used at the
beginning or end of a step and is rejected if used within a step.