Configuring the HMI system
2.1 Processing INI files
HMI Advanced (IM4)
50 Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
2.1.16 Activating the V.24 interface
Activating the V.24 interface
The serial V.24 interface can be activated in the DINO.INI file, section [System]. Here it is
possible to save files and assign them to the V.24/PG (COM1/COM2) interfaces.
The default setting is 0 (no interface parameterization).
[System]
; enable V24 setting by setting a non zero value
V24Settings=0
Procedure
To be able to use the V.24 data transfer with HMI-Advanced 7.5 on PCU 50.3, the following
steps are required:
1. In the BIOS of the PCU 50.3 under "Advanced → I/O Devices Configuration", set the
"Internal COM1" to "Disabled".
2. Insert the "PCI Interface Card (COM/LPT)" into the PCU 50.3 and install the supplied
driver.
3. In the Windows device manager, rename the COM interfaces as COM1, COM2.
4. In the Windows device manager, for each COM interface, under "Port Settings
Advanced", deactivate the "Enable CTS/RTS Auto Flow Control" option.
5. Activate the V.24 interface in the DINO.INI configuration file.
See also
DINO.INI (Page 277)

Table of Contents

Other manuals for Siemens SINUMERIK

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK and is the answer not in the manual?

Siemens SINUMERIK Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK
CategoryControl Unit
LanguageEnglish

Related product manuals