Programming
2.6 Methods
Expanding the user interface
2-66 Commissioning Manual, 11/2006, 6FC5397-0DP10-0BA0
2.6.5 UNLOAD
Description
The UNLOAD method is executed before a dialog is unloaded.
Programming
Syntax: UNLOAD
...
END_UNLOAD
Description: Unload
Parameters: - None -
Example
UNLOAD
REG[1] = VAR1 ; Save variable in register
END_UNLOAD
2.6.6 OUTPUT
Description
The OUTPUT method is executed if the "GC" function is called.Variables and Help variables
are configured as an NC code in an OUTPUT method. The individual elements in a code line
are linked by means of blanks.
Note
The NC code can be generated in an extra file by means of file functions and transferred to
the NC.