Tool management
6.1 Setting tool management parameters on the HMI
HMI Advanced (IM4)
182 Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
6.1.7 Magazine configuration
Create magazine configuration
For each TO unit, there is only one common magazine configuration for configuring the tool
management. A magazine configuration can consist of one or more real magazines. As one
TO unit can be assigned to several channels, this magazine configuration is available to the
associated channels simultaneously.
In this screen, new data required for the selected magazine is defined or existing data is
displayed.
Figure 6-11 Magazine configuration
Configurations
Name Name of the magazine configuration (max. 32 characters).
Tool search transfer from configuration (Default setting: Setting for
$TC_MAP10=0, NCK uses values from $TC_MAMP2).
active tool/min. duplo
Shortest path
active tool/min. $TC_TP10
Monitoring: min. actual value
Monitoring: max. actual value
Settings for the location coding can be variable (default) or fixed.
Exit the screen by pressing the "Cancel" or "OK" softkey.