Parameterizing machine data
3.1 Handling machine data via the HMI
HMI Advanced (IM4)
92 Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
● Unit of the machine data
● Effectiveness
Effectiveness of the machine data
The right-hand column indicates when a machine data becomes effective:
so = immediately effective
cf = when confirmed via the "Activate MD" softkey
re = reset
po = POWER ON (NCK Power On reset)
Physical units of the machine data
The physical units of machine data are displayed on the right-hand side of the input field:
Display Unit Measured quantity
m/s**2 m/s² Acceleration
rev/s**3 rev/s³ Acceleration change for the rotating axis
kg/m**2 kgm² Moment of inertia
mH mH (millihenry): Inductance
Nm Nm (Newton meters): Torque
us µs (microseconds): Time
µA µA (microamperes): Current magnitude
µVs µVs (microvolt-seconds): Magnetic flux
userdef user-defined: The units are defined by the user.
If the machine data does not use units, no units are displayed.
If the data are not available, the "#" symbol is displayed instead of the value. If the value
ends in an "H", it is a hexadecimal value.
3.1.1 Setting-up a display filter for machine data
Function
The purpose of the display filters offered for “General machined data” is to selectively reduce
the number of machine data displayed.
For this purpose, all machine data are assigned to certain display groups, e.g. configuration
data. The following applies:
● Each area has its own group organization.
● Each group corresponds to one bit in the word filter (previously a reserve)