List of the INI Files
A.16 MBDDE.INI
HMI Advanced (IM4)
300 Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
of this file
; the commented examples below correspond to the netnames.bsp
file delivered
[net TextFiles] (only for SINUMERIK powerline)
;PLCRechteNCU = f:\dh\mb.dir\rechts
;NCURechteNCU = f:\dh\mb.dir\rechts
;PLCMittlereNCU = f:\dh\mb.dir\mitte
;NCUMittlereNCU = f:\dh\mb.dir\mitte
;PLCLinkeNCU = f:\dh\mb.dir\links
;NCULinkeNCU = f:\dh\mb.dir\links
; drive and device type specific alarm text files
[DriveTextFiles]
ALDEV_80E5=f:\dh\mb.dir\aldvs_
ALDRV_80E5=f:\dh\mb.dir\aldrs_
;ALDEV_808F=f:\dh\mb.dir\aldvu_
;ALDRV_808F=f:\dh\mb.dir\aldru_
ALDEV_x=f:\dh\mb.dir\aldvp_
ALDRV_x=f:\dh\mb.dir\aldrp_
[IndexTextFiles]
ALNX=f:\dh\mb.dir\alnx_
ALSI=f:\dh\mb.dir\alsi_
; default definition of the priorities of the different alarm types
[DEFAULTPRIO]
CANCEL=100
RESET=100
POWERON=100
NCSTART=100
PLC=100
PLCMSG=100
MMC=100
; This section defines different characteristics of the log that
; specifies how particular error messages are to be registered.
[PROTOCOL]
Details on generating filter expressions to control the number of messages seen are
provided in the Chapter "Setting the memory space for the alarm log".
; Criteria for selecting the alarm messages to be recorded. The
notation
; is described in SINUMERIK 840D OEM package HMI User's Manual.
Filter=Expression
; Characterizes the numbers of entries in the log file. If the
actual
; number exceeds this value, the server starts to override old
entries