List of the INI Files
A.22 REGIE.INI
HMI Advanced (IM4)
316 Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
; Index of task started by the regie after power on
; (may differ in some circumstances from the default task index,
; which is the task index from [TaskConfiguration] with the lowest
number.
PoweronTaskIndex = 0
[StartupConfiguration]
OEM software in the range from 12 to 24 can be started in this section.
The [StartupConfiguration] section is subdivided as follows:
0 to 12 is reserved for expanded functionality provided by Siemens
12 to 24 free for OEM applications
25 to 32 reserved for simulation
33 to 47 reserved for Siemens applications (in the directory ADD_ON)
Example:
Startup33 = name := ITS, Timeout :=15000
Startup34 = name := HMIVers, Cmdline := "/StartUp", Timeout :=10000
[TaskConfiguration]
; 3. bar
; Task16 = name := oemframe, cmdline := "sysmeter", Timeout :=
10000,
; ClassName := "SysMeter", HeaderOnTop := False, PreLoad := False
The 3rd horizontal softkey bar is only displayed if, from task 16 onwards, a task or the EXIT
button has been assigned to it.
; 4th bar : located to task 96 - 103
;Task96 = name := oem, Timeout := 10000
;Task97 = name := oem, Timeout := 10000
;Task98 = name := oem, Timeout := 10000
;Task99 = name := oem, Timeout := 10000
;Task100 = name := oem, Timeout := 10000
;Task101 = name := oem, Timeout := 10000
;Task102 = name := oem, Timeout := 10000
;Task103 = name := oem, Timeout := 10000
The 4th horizontal softkey bar is only displayed if, from task 96 onwards, a task or the EXIT
button has been assigned to it. The task 50 to task 87 entries can be used by OEMs.
[CommandToTask]
; only necessary for HMI invocation through NCU via command channel
plc_select = #13
Cycles = #14
In this section, you can specify that the HMI will be started from the NCU via the command
channel.
References: Commissioning Manual "Supplement operator interface",
Chapter "Activating the dialog screen from the NC program"