Configuring the HMI system
2.1 Processing INI files
HMI Advanced (IM4)
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
31
Example
The following entries in the REGIE.INI clarify the process:
Skeleton application for user-specific operating trees.
; sample entry
Task7 = name := mntmmc, cmdline := "SectionName1", Timeout := 60000
The task number (7 in this case) is assigned to the softkey that
; calls the general application.
Task0: Horizontal softkey 1
...
Task7: Horizontal softkey 8
mntmmcis the name of a standard task for interpreting the softkeys in the skeleton
application in TASKCONF.INI and for activating them.
The value of cmdline indicates the section in the TASKCONF.INI file in which the softkey
assignments in the skeleton application are described in detail.
There may be more than one Task<No.>= name := mntmmc, ... entry if several sections in
TASKCONF.INI have been defined with skeleton application parameters. This also allows
operating trees to be designed with multiple levels.
[SectionName1]
; REGIE.INI must contain a reference to the section name selected by
the user.
;
; Sample entries:
; The Services application should be activated when the general
application
; is started for the first time.
; The softkey index is defined using the StartIndex entry
; that activates the required task when the program starts.
; Services with StartIndex 5 for example
StartIndex = 5
; Main screen for the skeleton application
Picture= Skeleton1.bmp
; The first softkey is assigned the task program (Taskindex 2)
; as child (HSK1IsTask=0) with parameter <root>
; the softkey texts for German are specified via default and English
(UK)
;
HSK1Task=2
HSK1IsTask=0
; application-specific parameters: Here, entry into the
; basic level of the application program, parameters: <root>
HSK1Command=<root>
HSK1SkText=Program
; No language specified is the default setting for all
; languages that are not configured
HSK1SKText _UK=Program
; softkey label in English (_UK)

Table of Contents

Other manuals for Siemens SINUMERIK

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK and is the answer not in the manual?

Siemens SINUMERIK Specifications

General IconGeneral
InterfaceEthernet, PROFIBUS, PROFINET, USB
Programming LanguagesDIN/ISO
DisplayTFT color display
CompatibilitySiemens drives and motors
SoftwareSINUMERIK Operate
Control Unit TypeCNC (Computer Numerical Control)
Safety FunctionsIntegrated safety functions up to SIL 3/PLe

Related product manuals