EasyManua.ls Logo

Siemens SINUMERIK

Siemens SINUMERIK
736 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Programming
2.6 Methods
Expanding the user interface
Commissioning Manual, 11/2006, 6FC5397-0DP10-0BA0
2-69
Example
OUTPUT(NC1) ; Only the variables of the original version are
made available in the OUTPUT block.
OUTPUT(NC1,1) ; The variables of the original version and the
expansions with version identifier 1 are made
available in the OUTPUT block
The OUTPUT block for the original version does not need a version identifier, however you
can specify it with 0. OUTPUT(NC1) is equivalent to OUTPUT(NC1,0). Version identifier n in
the OUTPUT block includes all variables of the originals 0, 1, 2, ... up to and including n.
Programming with version identifier
//M(XXX) ; Version 0 (default)
DEF var100=(R//1)
DEF var101=(S//"Hello")
DEF TMP
VS8=("GC")
PRESS(VS8)
GC("NC1")
END_PRESS
OUTPUT(NC1)
var100",,"var101
END_OUTPUT
; ************ Version 1, extended definition ***************
//M(XXX)
DEF var100=(R//1)
DEF var101=(S//"Hello")
DEF var102(1)=(V//"HUGO")
DEF TMP
VS8=("GC")
PRESS(VS8)
GC("NC1")
END_PRESS
...
OUTPUT(NC1) ; Original and the new version in addition
var100","var101
END_OUTPUT
...

Table of Contents