Technical data
12.6 Electrical data
SIPART PS2 with and without HART
242 Operating Instructions, 10/2013, A5E00074631-11
Basic device without
explosion protection
Basic device with
explosion protection
Ex d
Basic device with
explosion protection
Ex "ia"
Basic device with
explosion protection
Ex "ic", "nA", "t"
For connecting to circuits with
the following peak values
- - U
n
= DC 30 V
I
i
= 100 mA
P
i
= 1 W
"ic":
U
i
= 30 V
I
i
= 100 mA
"nA"/"t":
U
n
≤ 30 V
(terminals 2/4 and 6/8)
6DR52.. With HART, explosion-protected
6DR53.. Without HART, not explosion-protected
Auxiliary power supply U
H
• Current consumption I
H
(V
H
- 7.5 V)/2.4 kΩ [mA]
For connecting to circuits with
the following peak values
- - U
n
= 30 V
I
i
= 100 mA
P
i
= 1 W
"ic":
U
i
= 30 V
I
i
= 100 mA
"nA"/"t":
U
n
≤ 30 V
n
Effective inner capacitance C
i
Effective inner inductance L
i
Galvanic isolation Between U
H
and I
W
Between U
H
and I
W
Between U
H
and I
W
(2 intrinsically safe
Between U
H
and I
W
Basic device without
explosion protection
Basic device with
explosion protection
Ex d
Basic device with
explosion protection
Ex "ia"
Basic device with
explosion protection
Ex "ic", "nA", "t"
• Screw terminals
2.5 AWG28-12
• Cable gland
M20x1.5 or
½-14 NPT
Ex d certified
M20x1.5;
½-14 NPT or
M20x1.5 or
½-14 NPT
M20x1.5 or
½-14 NPT
Female thread G¼ or ¼-18 NPT