Alarm, error, and system messages
10.1 Output of system messages in the display
SIPART PS2 with and without HART
Operating Instructions, 10/2013, A5E00074631-11
205
Message
Line
Meaning / cause
Remedy
Up
Down
NOZZL X Actuator stops (the initialization process was
interrupted using the "-" button when the
actuation speed display was active)
The travel time can be changed by
adjusting the restrictor(s)
Redetermine the speed of shifting using
the "-" button
Continue with the "+" button
TESt
X
Leakage test active (the "+" button was
pressed when the actuation speed display
was active)
Wait for 1 minute
Continue with the "+" button
LEAKG X
nn.n
X
Value and unit of the result after the leakage
test
Rectify the leakage if the value is too
large
Continue with the "+" button
%/MIN X
nn.n
X
Initialization completed successfully with the
display of actuator travel or the actuator
angle
Acknowledge by pressing the operating
mode button briefly and exit the
configuration level by pressing it longer
FINISH X
See also
System messages before initialization (Page 201)
10.1.3
System messages when exiting the Configuration mode
Remarks about the tables:
nn
stands for variable numeric values
Error symbol
/
(slash): the text to the left and right of the slash blink interchangeably.
Messages when exiting the configuration mode:
Message
Goals
Operating mode
Meaning / Cause
Measure
Up
Down
Automatic
Manual mode
P Manual mode
n.nn.nnV
ER
X
X
Software version
Wait
ErrorSLn
n
X
X
Monotony interruption
of the free
characteristic on the
setpoint turning point
n
Correct value

Table of Contents