79
F. Replace Worn Model (or Support) tip.
The system tracks the amount of material extruded through a tip. You will receive this prompt when
tip performance may start to become compromised. (Tip-life prediction is an estimated value. Many
factors contribute to actual tip-life aside from amount of material extruded. Actual tip-life may differ
from predicted tip-life.)
Replace the flagged tip.
G. Model / Support Material Incompatibility.
Model and support materials are not of compatible types.
Load correct material.
H. Vacuum not present. Check the build sheet
Vacuum is below minimum for system operation.
Correct condition - often the result of a poorly positioned build sheet.
I. Continue.
You can choose to ignore the warning and ‘Continue’ the build, but part build quality will be
unpredictable.
Note: A warning generated from a mis-match of model/support compatibility or
from low vacuum cannot be bypassed.