4.5.1.5 Drain deposit in fuel tank
(1) To facilitate access, swing
upper-structure 90°.Stop the machine
at level ground as shown in fig.
(2) Lower bucket to the ground.
(3) Run engine unloaded at low speed
for 5 minutes.
(4) Shut off engine and take out
key.(before start the machine)
(5) Pull pilot control cut off rod to the
“lock” position
(6) Loosen drain valve underneath fuel
oil tank to drain water and deposit,
then close drain valve.
4.5.1.6 Check hose and piping for leakage,
interference abrasion
Warning
Pressurized fluid can penetrate skin
causing serious injury.
To prevent being injured, use a card
board to search leakage. Be careful
not to allow high-pressure fluid to
come into contact with body.
In case of accidents, contact
experienced doctor for medical
attention.
Warning
Exposed hydraulic oil and lubricant
can cause fire and injury to person.
To avoid this hazard:
Stop the machine to firm level ground, lower
bucket to ground.