3.3.8.3 Display range and alarm statement
Water temperature meter: Displayed by finger and numerical. If water temperature over than pre-set,
corresponding label will displayed in warning labels area; 2 seconds later, the red indicator light lights on and
the buzzer activated. This fault will be recorded.
Fuel meter: Displayed by finger and numerical. If fuel level lower than warning level, corresponding label will
displayed in warning labels area; 10 seconds later, the red indicator light lights on and the buzzer activated.
This fault will be recorded.
Working hours: Displays 6 digits (includes 1 digit behind radix point), displays 99999.9 hours at most; when
the machine is working (rotating speed fast than 200r/min or oil pressure over 0.1 Mpa), the meter begins to
count.
Voltage: Displayed numerically. Display the real value of voltage.
Rotating speed meter: Displayed numerically. Display range form 0 to 9999r/min. Number of tooth is optional
from 0 to 999.99.
Air filter: When air filter jam-up alarm switch earths, 5 seconds later, corresponding label will displayed in
warning labels area; the red indicator light lights on and the buzzer activated.
Oil filter: When oil filter jam-up alarm switch earths, 5 seconds later, corresponding label will displayed in
warning labels area; the red indicator light lights on and the buzzer activated.
Charge indication: When generator stopped, corresponding label and description will be displayed in monitor.
Pre-heat indication: Input 12V power supply, the indicator lights on. And description will be displayed.